Part # CSS-M4-4, Stainless Steel Standoffs - Types CSS, CSOS - Metric


    Download PDF Download PDF   
    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

These standoffs ensure permanent mounting in metal sheets as thin as 1.60mm.

The fastener head is locked securely in a blind, milled hole and is able to handle substantial loads. The concealed-head feature allows the side of the sheet opposite installation to remain smooth.

Sheet preparation only requires a milled blind hole to the recommended minimum depth. Center-cutting end mills for hole preparation are available from PennEngineering. Installation of the concealed-head studs and standoffs is simple using a hollow anvil and solid punch. Place the head of the fastener in the hole and insert using any standard press. Displaced sheet metal flows smoothly around the head into the undercut.





 Specifications   

Thread Size x Pitch

M4 x 0.7

Thread Code

M4

Length Code

4

Material Code

S

Style

#1

Shank

Short

Min. Sheet Thickness

1.6 mm

Blind Mounting Hole Diameter + 0.08

7.92 mm

Min. Depth of Blind Hole1

1.10 mm

L - Length + 0.05 –0.13

View
4 mm

A Max.

1.04 mm

B Max.2

6.23 mm

C Max.

7.9 mm

H Nom.

8.74 mm

Min. Dist. Hole C/L to Edge

6.4 mm

For Use in Sheet Hardness

HRB 70 / HB 125 or Less

Thread Specification

Internal, ANSI / ASME B1.13M, 6H

Fastener Material

300 Series Stainless Steel

Standard Finish

Passivated and/or tested per ASTM A380

Min. Depth Full Thread F

6.5 mm

CAD Supplier

PennEngineering® (PEM®)
1 Blind mounting holes may be deeper than minimums except where sheet material is at or near minimum thickness. Fasteners should always be installed so the flange is flush with the surface of the sheet.